(b) moduleStatusMm group (6/7)
Object
No
identifier
37
mmVoltSensor8
Valid
38
mmVoltSensor9
Name
39
mmVoltSensor9
Value
40
mmVoltSensor9
Valid
41
mmTemperatur
eTable
42
mmTemperatur
eEntry
43
mmTempIndex
44
mmTempSenso
r1Name
(*1)
"unknown" is shown in the process of setting redundancy, or when no management
module is installed or the status cannot be obtained.
(*2)
"unknown" is shown when no management module is installed or the status cannot be
obtained. "power-off" is shown after executing SDN in the process of setting
redundancy.
(*3)
"0" is shown as the number of sensor when no management module is installed.
(*4)
"Not install" is shown if no management module is installed or redundancy setting is on
the process; "Cannot get data" is shown if the data cannot be obtained.
(*5)
"0" is shown if no management module is installed or redundancy setting is on the
process, if the data cannot be obtained, or if no sensor exists.
(*6)
"invalid" is shown if no management module is installed or redundancy setting is on the
process; "unknown" is shown if no data is obtained".
OID
Syntax
.1.3.6.1.4.1
INTEGER
.116.5.39.3
.3.2.1.25
.1.3.6.1.4.1
Display
.116.5.39.3
String
.3.2.1.26
.1.3.6.1.4.1
Integer32
.116.5.39.3
.3.2.1.27
.1.3.6.1.4.1
INTEGER
.116.5.39.3
.3.2.1.28
.1.3.6.1.4.1
Not-
.116.5.39.3
Accessible
.3.3
.1.3.6.1.4.1
Not-
.116.5.39.3
Accessible
.3.3.1
.1.3.6.1.4.1
Integer32
.116.5.39.3
.3.3.1.1
.1.3.6.1.4.1
Display
.116.5.39.3
String
.3.3.1.2
1675
Access
Description
Shows the voltage value
RO
validity of the management
module in the slot shown in
#5. One of the following
values is shown. (*6)
1: invalid
2: valid
3: unknown
RO
Shows the voltage sensor
name for the management
module in the slot shown in #5.
(*4)
Shows the voltage value of
RO
the management module in
the slot shown in #5. (*5)
The value is shown using the
unit of 0.1V. The actual value
is one-tenth of the response
value.
RO
Shows the voltage value
validity of the management
module in the slot shown in #5.
One of the following values is
shown. (*6)
1: invalid
2: valid
3: unknown
NA
Shows the table of information
on the management module
temperature sensor.
NA
Shows the table entry
describing the information on
the management module
temperature sensor.
RO
Shows the index value ranging
from 1 to chassisCapacityMm
to identify the table entry.
RO
Shows the temperature sensor
name for the management
module in the slot shown in #5.
(*4)