2-12 Functional overview
A list of the recommended DIP switch settings appears in the following table.
Table 4 Recommended NT6X21AD S1 DIP switch settings
Recommended
application
P-phone sets long
loop: 19-24dB
EML
P-phone sets
medium loop:
4-17dB EML
P-phone sets
short loops: 0-4dB
EML
Northern Telecom
UDLCs
Other vendors
UDLCs
6X21AC
equivalent mode
Note: dB=decibel
NL = non-loaded
9+2=loaded (900 ohm + 2.16 micro-farads) network
Vpp=voltage peak to peak
EML= estimated measured loss, as defined in NTP 297-2011-180 BCS35 version 01.02
A list of two acceptable limits for transhybrid loss (THL) appear in the
following tables. The limits depend on the D/A level selected. The
NT6X21AD line card uses the same diagnostics as the NT6X21AC line card.
Because of this event, the THL limits are modified for diagnostics purposes.
297-8361-550 Standard 04.02 December 2004
D/A voice
S1
Switch position
Switch position
ON
OFF
ON
0dB
-3.5dB
NL
X
X
X
X
X
X
Balance
S2
Both
OFF
ON
1.3Vp
9+2
p
X
X
X
X
X
X
X
X
Signaling level
S3 and S4
Only
Only
Both
S4 ON
S3 ON
OFF
0.8Vp
0.6Vp
0.14
p
p
Vpp
X
X
X
X

Advertisement