Table 9 FSP circuit breaker assignments
CB
Shelf type
CB6
LCA
CB7
LCA
CB8
FSP
CB9
FSP

Software description

The following sections describe the software operation of the NTX146AA
feature package.
Interface to DS-1 links
The OPM provides an interface between the host controller and a maximum of
640 subscriber lines through the DS-1 links. The LCCs reassign data carried
over the 32 channels of a DS30A link to the 24 channels of an equivalent DS-1
link. The six additional channels are for intraswitching and signaling use.
LCC control data
Before a unit of the OPM changes to InSv, the LCM sends control data to LCC
for that unit. The control data indicates the number of DS-1 cards equipped
and the clock source the OPM must use. The LCM receives this data from the
host LTC/LGC. The host sends messages to the LCM unit during return to
service (RTS). The host also sends messages to the LCM unit. This event
occurs when the CC attempts to switch the LCM clock source from LCC to
LCC.
The OPM software controls the LCC clock source, which is frequency-locked
to the primary DS-1 links. The OPM software does not control the LCC clock
source when the two units of the LCM are not active. When both units are not
active, LCM hardware forces each LCM unit to take a clock source from the
LCC. This clock source belongs to the LCM unit.
Other host office functions
The software resident in the host DMS-100 Family office controls the
following functions:
Shelf pos.
04
21
72
72
class-of-service
code interpretation
screening
routing
billing
DMS-100 Family OPM Maintenance Manual ISN07 (TDM)/SN07 (DMS) and up
Slot pos.
PEC code
05
NT6X53
05
NT6X53
1-4
T-1 repeaters
5-7
T-1 repeaters
Functional overview 2-27
Equipment
LCM unit 0
LCM unit 1
T-1 repeaters
T-1 repeaters