Nortel DMS-100 Series Maintenance Manual page 239

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Clearing an LCM (RG) critical alarm associated with a ringing generator
Enter this procedure from the PM system level alarm clearing procedure
step. This step must identify a PM alarm associated with an OPM
ringing generator fault.
At the MAP terminal
1
To silence the alarm, type
>MAPCI;MTC;PM;SIL
and press the Enter key.
2
To identify the PM that has faults, type
>DISP STATE ISTB LCM
and press the Enter key.
3
To post the ISTb PM identified in step 2, type
>POST LCM site frame_no lcm_no
and press the Enter key.
where
site
is the name of the site where the PM is located
frame_no
is the number of the PM frame (00 to 99)
lcm_no
is the number of the LCM (0 or 1) in the frame
Example of a MAP display:
SysB
PM
1
LCM
1
LCM
REM1
14 1 ISTb
Unit0:
SysB
Unit1:
ISTb
Drwr:
01
23
..
..
4
To check for fault indicators, type
>QUERYPM
FLT
and press the Enter key.
OPM alarm clearing procedures
ATTENTION
ManB
OffL
CBsy
0
2
0
2
Links_OOS:
/RG: 0
/RG: 0
11
11
45
67
89
01
23
..
..
..
..
..
DMS-100 Family OPM Maintenance Manual XPM14 and up
critical
ISTb
InSv
0
0
12
0
0
CSide
0
PSide
0
11
11
11
RG:Pref 0 ISTb
45
67
89
Stby 1 ISTb
..
..
..
7-19
LCM (RG)
(continued)