Figure 18 SREX scheduling
LCM 0
1
Note 1: The REX tests can run on LCM 0 and LCM 1 at the same time as
REX tests that run on RCC 0 and LGC 0.
Note 2: The REX tests cannot be run on LCM 2 through LCM 7 if a REX
test runs on LGC 0.
Separate the LCM_REX_TEST and the LCMCOV_REX_TEST. This action
allows faster completion of site REX_TEST coverage. The
LCM_REX_TESTs works without constraints of the converter voltage and
ring tests. The LCM_REX_TESTs can run at the same time and scheduled
separately for optimum execution periods.
Note: Perform LCMCOV_REX_TEST on LCMs, XLCMs and OPMs.
Feature AF3234 provides the following REX test improvements for LCM
peripherals and the variants, like LCME:
ESA REX test
LCM and ESA-independent REX test
MAP command for manual REX test
fault indicators
DMS-100 Family OPM Maintenance Manual ISN07 (TDM)/SN07 (DMS) and up
Network
LTC 0
RCC 0
OPM 0
OPM 0
Functional overview 2-67
LGC 0
LCM 2
7