Nortel DMS-100 Series Maintenance Manual page 540

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-200 OPM card replacement procedures
NT6X75
in an OPM HIE
9
At the OPM cabinet
10
11
At the MAP terminal
12
13
14
297-8361-550 Standard 04.01 September 2000
(continued)
lcm
is the number of the LCM in the OPM cabinet
Busy unit 0 by typing
>BSY UNIT 0
and pressing the Enter key.
Replace the NT6X75 card using the common replacing a card procedure in
this document. When you have completed the procedure, return to step 11 of
this procedure.
If you were directed to this procedure from the Alarm Clearing Procedures ,
return now to the alarm clearing procedure that directed you here. Otherwise,
continue with step 12.
Return to service unit 0 by typing
>RTS UNIT 0
and pressing the Enter key.
If RTS
passed
failed
Post the ESA processor identified in step 5 by typing
>POST ESA esa_no
and pressing the Enter key.
where
esa_no
is the number of the ESA processor
Load the ESA processor by typing
>LOADPM
and pressing the Enter key.
If
message "loadfile not found in
directory" is received
load passed
load failed
Do
step 13
step 36
Do
step 15
step 33
step 36

Advertisement

Table of Contents
loading

Table of Contents