2-60 Functional overview
The PM132 displays a combined report of each drawer-level test in a set LCM.
The PM132 indicate the following:
Refer to the chapter OPM/OPM related logs for the syntax of test result
reasons.
Equipment that is not available does not allow the LCM-level test to run before
each drawer tests. When this event occurs, the system does not test the LCM.
The system generates a PM181 log and the LCM node state does not change.
When a drawer test fails to run, the drawer remains in the current state. The
system tests the drawer again in a later window.
QUERYPM FLT command
Additional information to the QUERYPM FLT command is present at the
MAP display level of the LCM. This information lists all drawers that fail the
BRT and are set ISTb. The node ISTb reason is reset to DRAWER FAULT.
297-8361-550 Standard 04.02 December 2004
test passes
reversal test fails
test does not run because line card is not available
test does not run because of problems encountered with the MTE
test does not run because test aborted
test does not run because drawer was previously out-of-service
test does not run because of call processing is in progress
test does not run because of bad hardware
test does not run because of message link problems
test does not run because resources are not available
test does not run because of an invalid load in the LCM
test does not run because of an error condition the system did not expect
test runs but drawer failed to RTS after test
test does not run because of conflicts in maintenance software