Nortel DMS-100 Series Maintenance Manual page 322

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

7-102 OPM alarm clearing procedures
ESA
critical, minor
(continued)
Clearing ESA critical, minor alarms
At the MAP terminal
1
2
3
4
5
297-8361-550 Standard 04.01 September 2000
Enter this procedure from a PM system level alarm clearing procedure step.
This step identifies a PM alarm that associates with an OPM fault.
To silence an audible alarm, type:
>MAPCI;MTC;SIL
and press the Enter key.
To access the PM level of the MAP display, type:
>PM
and press the Enter key.
To identify the central-side busy (CBsy) ESA processor, type:
>DISP STATE CBSY
and press the Enter key.
If ESA
is CBsy
is not CBsy
To post the ESA processor, type:
>POST ESA esa_no
and press the Enter key.
where
esa_no
is the number of the ESA processor (0 to 255)
Example of a MAP response :
REM1
ESA
0 CBsy
To display the C-side links and identify the associated OPMs, type:
>TRNSL
and press the Enter key.
ATTENTION
ESA
Do
step 4
step 11