Replacing an NT6X54 in an OPM
At your Current Location
1
If you are entering this procedure due to a loss of power in the LCM's controller
(LGC/LTC/RCC), check logutil for PM181 log with reason text of: DCC BIC
Looparound and go to step 10.
Proceed only if you have been directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure for verifying
or accepting cards, or have been directed to this procedure by your
maintenance support group.
2
Obtain a replacement card. Ensure the replacement card has the same
product equipment code (PEC), including suffix, as the card that is to be
removed.
If you were directed to this procedure from the Alarm Clearing Procedures ,
3
go to step 10. Otherwise, continue with step 4.
At the MAP terminal
4
Access the peripheral module (PM) level of the MAP (maintenance and
administration position) display and post the OPM by typing
>MAPCI;MTC;PM;POST OPM site frame opm
and pressing the Enter key.
where
site
is the site name (alphanumeric) of the OPM
frame
is the frame number (0 through 511) of the OPM cabinet
lcm
is the number (0 or 1) of the LCM
Example of a MAP display:
OPM card replacement procedures
ATTENTION
DMS-100 Family OPM Maintenance Manual XPM14 and up
NT6X54
in an OPM
(continued)
8-167