8-194 OPM card replacement procedures
NT6X74
in an OPM RMM
14
15
16
17
18
19
20
21
22
297-8361-550 Standard 04.01 September 2000
(continued)
Download the tape by typing
>MOUNT tape_no
and pressing the Enter key.
where
tape_no
is the number of the tape drive containing the PM load files
List the contents of the tape in your user directory by typing
>LIST T tape_no
and pressing the Enter key.
where
tape_no
is the number of the tape drive containing the PM load files.
Demount the tape drive by typing
>DEMOUNT T tape_no
and pressing the Enter key.
where
tape_no
is the number of the tape drive containing the PM load files.
Go to step 27.
From office records, determine and note the number of the input/output
controller (IOC) disk and the name of the volume that contains the PM load
files.
Access the disk utility level of the MAP by typing
>DSKUT
and pressing the Enter key.
List the IOC file names into your user directory by typing
>LISTVOL volume_name ALL
and pressing the Enter key.
where
volume_name
is the name of the volume that contains the PM load files, obtained in
step 17.
Leave the disk utility by typing
>QUIT
and pressing the Enter key.
Go to step 27.
From office records, determine and note the number of the system load
module (SLM) disk and the name of the volume that contains the PM load
files.