22
Determine if a Converter Fail LED is lit.
If Converter Fail LED is
lit
not lit
At the MAP display
23
Access the PM level of the MAP display by typing
>MAPCI;MTC;PM
and pressing the Enter key.
24
Post the OPM that is controlled by the alarm and control card as recorded in
step 5 by typing
>POST LCM
and pressing the Enter key.
where
site_name
is the name of the site where the LCM is located
frame_no
is the number of the frame where the LCM is located
lcm_no
is the number of the LCM unit associated with the faulty card
25
Return to service LCM unit 1 by typing
>RTS
UNIT 1
and pressing the Enter key.
26
The next action depends on your reason for performing this procedure
If you were
directed to this procedure from a
maintenance procedure
not directed to this procedure
from a maintenance procedure
27
Return to the maintenance procedure that sent you to this procedure and
continue as directed.
28
For further assistance, contact the personnel responsible for the next level of
support.
29
You have completed this procedure.