Nortel DMS-100 Series Maintenance Manual page 435

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Replacing an NT6X18 card in an OPM
At your current location
1
Obtain a replacement card. Ensure that the replacement card has the same
product equipment code (PEC), including suffix, as the card that is to be
removed.
At the MAP terminal
2
Access the LTP level of the MAP and post the line associated with the card to
be replaced by typing
>MAPCI;MTC;LNS;LTP;POST L site lcm lsg ckt
and pressing the Enter key.
where
site
is the name of the site where the OPM is located
lcm
is the number of the OPM with the faulty card
lsg
is the number of the line subgroup with the faulty card
ckt
is the number of the circuit associated with the faulty card
Example of a MAP response:
LCC PTY RNG .....LEN.........
1FR
REM1 00 0 03 03
3
Check the status of the posted line.
If the line status is
manual busy (ManB)
not ManB
4
Busy the line by typing
>BSY
and pressing the Enter key.
5
Go to the common replacing a line card procedure in this document. When
you have completed the procedure, return to this point.
OPM card replacement procedures
DMS-100 Family OPM Maintenance Manual XPM14 and up
in an OPM
DN
STA F S LTA TE RESULT
7213355 MB
Do
step 5
step 4
8-95
NT6X18
(continued)