Nortel DMS-100 Series Maintenance Manual page 542

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-202 OPM card replacement procedures
NT6X75
in an OPM HIE
24
25
26
27
28
29
30
31
32
297-8361-550 Standard 04.01 September 2000
(continued)
List the IOC file names into your user directory by typing
>LISTVOL volume_name ALL
and pressing the Enter key.
where
volume_name
is the name of the volume that contains the PM load files, obtained in
step 22.
Leave the disk utility by typing
>QUIT
and pressing the Enter key.
Go to step 32.
From office records, determine and note the number of the system load
module (SLM) disk and the name of the volume that contains the PM load
files.
Access the disk utility level of the MAP by typing
>DISKUT
and pressing the Enter key.
List the disk volume names for both S00D and S01D by typing
>LV CM
and pressing the Enter key.
List the SLM file names into your user directory by typing
>LF volume_name
and pressing the Enter key.
where
volume_name
is the name of the volume that contains the PM load files, obtained in
step 27.
Leave the disk utility by typing
>QUIT
and pressing the Enter key.
Reload the ESA processor by typing
>LOADPM
and pressing the Enter key.
If
load failed
load passed
Do
step 36
step 33

Advertisement

Table of Contents
loading

Table of Contents