Nortel DMS-100 Series Maintenance Manual page 560

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-220 OPM card replacement procedures
NTMX45
in an OPM HIE
16
17
18
19
20
21
22
23
24
25
26
297-8361-550 Standard 04.01 September 2000
(continued)
tape_no
is the number of the tape drive containing the PM load files
Go to step 27.
From office records, determine and note the number of the input/output
controller (IOC) disk and the name of the volume that contains the PM load
files.
Access the disk utility level of the MAP display by typing
>DSKUT
and pressing the Enter key.
List the IOC file names into your user directory by typing
>LISTVOL volume_name ALL
and pressing the Enter key.
where
volume_name
is the name of the volume that contains the PM load files, obtained in
step 17
Leave the disk utility by typing
>QUIT
and pressing the Enter key.
Go to step 27.
From office records, determine and note the number of the system load
module (SLM) disk and the name of the volume that contains the PM load
files.
Access the disk utility level of the MAP display by typing
>DISKUT
and pressing the Enter key.
List all SLM disk volumes into your user directory by typing
>LV CM
and pressing the Enter key.
List the SLM file names into your user directory by typing
>LF volume_name
and pressing the Enter key.
where
volume_name
is the name of the volume that contains the PM load files, obtained in
step 22
Leave the disk utility by typing
>QUIT
and pressing the Enter key.

Advertisement

Table of Contents
loading

Table of Contents