Nortel DMS-100 Series Maintenance Manual page 383

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Replacing an NT2X11 card in an RMM
At your current location
1
Obtain a replacement card. Ensure that the replacement card has the same
product equipment code (PEC), including suffix, as the card to be removed.
At the MAP display
2
Access the TTP level of the MAP and post the line test unit to be replaced by
typing
>MAPCI;MTC;TRKS;TTP;POST T LTU ltu_no
and pressing the Enter key.
where
ltu_no
is the number of the line test unit which is to be replaced
Example of a MAP response:
LAST CIRCUIT = 27
POST CKT IDLED
SHORT CLLI IS:
OK, CLLI POSTED
POST
TTP 6–006
CKT TYPE
OG
3
Busy the trunks that are associated with the card to be replaced by typing
>BSY
and pressing the Enter key.
OPM card replacement procedures
in an OPM RMM
LTU
DELQ
BUSY Q
PM NO.
COM LANG
RMM 0 0
LTU
DANGER
Briefly state reasons for the warning
Enter the reasons for the warning: a warning informs the
reader of a risk of service interruption, or damage to
equipment, or both.
DMS-100 Family OPM Maintenance Manual XPM14 and up
DIG
STA S R DOT TE R
21
LO
P_IDL
8-43
NT2X11
(continued)