7-84 OPM alarm clearing procedures
LCM
minor
(continued)
Clearing an LCM minor alarm
At the MAP terminal
1
2
3
4
297-8361-550 Standard 04.01 September 2000
Enter this procedure from a PM system level alarm clearing procedure step
that identified a PM alarm associated with an OPM fault.
To silence an audible alarm, type
>MAPCI;MTC;SIL
and press the Enter key.
To access the PM level of the MAP display, type
>PM
and press the Enter key.
To identify the OPM that has faults, type
>DISP STATE ISTB LCM
and press the Enter key.
To post the LCM with the alarm condition, type
>POST LCM site frame lcm
and press the Enter key.
where
site
is the site name of the OPM (alphanumeric)
frame
is the frame number of the OPM (0 to 511)
lcm
is the number of the LCM
Example of a MAP response:
LCM
REM1 00 0
Unit0: InSv
Unit1: SysB
Drwr:
01 23 45 67 89 01 23 45 67 89
.. .. .. .. .. .. .. .. .. ..
ATTENTION
ISTb
Links OOS: Cside
/RG: 0
/RG: 0
11 11 11 11 11 RG: Pref 0 InSv
0 Pside
0
Stby 1 InSv