8-112 OPM card replacement procedures
NT6X27
in an OPM HIE
6
7
8
9
297-8361-550 Standard 04.01 September 2000
(continued)
Display P-side link information by typing
> TRNSL P
and pressing the Enter key.
Example of a MAP response:
Link 2: ILCM REM1 00 0
Link 6: ILCM REM1 00 0
Record the numbers of the links with status not OK.
Use the following diagram to determine which PCM-30 interface card or
cards corresponds to the links identified as faulty in step 6. Note that each
NT6X27 card has 2 ports. For example, the faulty link 6 displayed in step 6
is connected to port 1 as indicated, which corresponds to the NT6X27 in slot
20.
Port numbers
Slot numbers
Determine the slot location of the faulty card.
If faulty card is in slot
19 or 20 of the HIE
21 of the HIE
Post the ILCM by typing
>POST ILCM site frame lcm_no
and pressing the Enter key.
where
site
is the name of the PRLCM site (alphanumeric)
frame
is the frame number of the PRLCM cabinet
Icm_no
is the number of the ILCM
NT6X27 port numbers
0;Cap MS;Status:OK
1;Cap MS;Status:SysB ;MsgCond: CLS
6
6
6
X
X
X
2
2
2
7
7
7
0
1
4
2
3
5
19
20
21
Do
step 9
step 12
;MsgCond: OPN