8-66 OPM card replacement procedures
NT2X70
in an OPM HIE
12
At the MAP display
13
14
15
16
297-8361-550 Standard 04.01 September 2000
(continued)
If you were directed to this procedure from another maintenance procedure,
return now to the procedure that directed you here and continue as directed;
otherwise, continue with step 13.
Post the OPM associated with the faulty NT2X70 card by typing
>POST LCM site_name frame_no lcm_no
and pressing the Enter key.
where
site_name
is the name of the site where the OPM is located
frame_no
is the number of the frame where the LCM is located
lcm_no
is the number of the LCM module in the frame
Return LCM unit 0 to service by typing
>RTS UNIT
0
and pressing the Enter key.
If RTS
passed
failed
Post the ESA processor associated with the faulty NT2X70 card by typing
>POST ESA esa_no
and pressing the Enter key.
where
esa_no
is the number of the ESA processor identified in step 4.
Load the ESA processor by typing
>LOADPM
and pressing the Enter key.
If
message "loadfile not found in
directory" is not received
load passed
load failed
Do
step 15
step 73
Do
step 17
step 33
step 37