Summary of card replacement procedures for an NT6X73 card in an HIE
At the PM level of
the MAP terminal,
post the LCM
Busy the LCM
unit associated
with faulty card
Replace card with
one of identical
PEC code
Return the LCM
unit to service
This procedure is
complete
Replacing an NT6X73 card in an HIE
At your Current Location
1
2
3
Proceed only if you have been directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure for verifying
or accepting cards, or have been directed to this procedure by your
maintenance support group.
Obtain a replacement card. Ensure the replacement card has the same
product equipment code (PEC), including suffix, as the card to be removed.
If you were directed to this procedure from another maintenance procedure,
go to step 7. Otherwise, continue with step 4.
DMS-100 Family OPM Maintenance Manual XPM14 and up
OPM card replacement procedures
in an OPM HIE
This flowchart summarizes the
procedure.
Use the instructions that follow
this flowchart to perform the
procedure.