Nortel DMS-100 Series Maintenance Manual page 411

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

45
If you were directed to this procedure from another maintenance procedure,
return now to the procedure that directed you here and continue as directed;
otherwise, continue with step 46.
At the MAP display
46
Post the OPM associated with the faulty NT2X70 card by typing
>POST LCM site_name frame_no lcm_no
and pressing the Enter key.
where
site_name
is the name of the site where the OPM is located
frame_no
is the number of the frame where the LCM is located
lcm_no
is the number of the LCM module in the frame
47
Return LCM unit 1 to service by typing
>RTS UNIT
and pressing the Enter key.
If RTS
passed
failed
48
Post the ESA processor associated with the faulty NT2X70 card by typing
>POST ESA esa_no
and pressing the Enter key.
where
esa_no
is the number of the ESA processor identified in step 4.
49
Load the ESA processor by typing
>LOADPM
and pressing the Enter key.
If
message "loadfile not found in
directory" is not received
load passed
load failed
OPM card replacement procedures
1
DMS-100 Family OPM Maintenance Manual XPM14 and up
in an OPM HIE
Do
step 48
step 73
Do
step 50
step 68
step 73
8-71
NT2X70
(continued)