8-210 OPM card replacement procedures
NT8X02
in an OPM BCU
Replacing an NT8X02 card in an BCU
At your Current Location
1
2
3
At the MAP terminal
4
5
297-8361-550 Standard 04.01 September 2000
(continued)
Proceed only if you have been directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure for verifying
or accepting cards, or have been directed to this procedure by your
maintenance support group.
Obtain a replacement card. Ensure the replacement card has the same
product equipment code (PEC), including suffix, as the card to be removed.
If you were directed to this procedure from the Alarm Clearing Procedures ,
go to step 6. Otherwise, continue with step 4.
Post the OPM PES with the BCU containing the battery charger controller
(BCC) card to be replaced by typing
>MAPCI;MTC;PM;PES;POST opmpes
and pressing the Enter key.
where
opmpes
is the PES discrimination number (0 to 199)
Example of a MAP response:
OPMPES
OPMPES
Common
Rectifiers
AC
FL0 FL1 CL0 CL1
.
.
BCC
0
1
0=W
BSY BSY BSY BSY EHT ELT
1=W
BSY BSY BSY BSY
Busy the BCC driver (BCCDVR) card by typing
>BSY BCCDVR
and pressing the Enter key.
RED
AMBER
1
2
2 Cond: GREEN
REM2
BCCDVR
.
.
.
2
3
Temp
FRNT SIDE
.
.
GREEN
OFFL
3
4
2
1
RMM
Audit Week
HBT
.
2
.
PESALRM
ECU FSP
s
.
.
Door
BCCFUSES
0
1
.
.
.
.
2
.