7-32 OPM alarm clearing procedures
LCM talk battery alarm
critical
(continued)
30
At the OPM site
31
32
33
297-8361-550 Standard 04.01 September 2000
pm_type
is the host peripheral (LGC, LTC, RCC, or RCC2)
pm_no
is the number of the peripheral (0 or 256)
link_no
is the number of the link associated with the host XPM. See step 24
display.
When the MORE ... prompt appears, use the NEXT command to view
additional links.
Example of a MAP response:
N CLASS SITE LTC CK D ALRM SLIP FRME BER
0 REMOTE HOST 0
Offline the links to prevent alarms and to reset the counters after the
restoration of the links occurs. To offline the links, type
>OFFL item_no
and press the Enter key.
where
item_no
is the item number under the n (0-4) column
Note: Perform this step for each link busied in step 27.
Remove the fuses and unseat the repeaters for the affected LCM unit.
If affected LCM unit
is unit 0
is unit 1
Remove the fuses and repeaters associated with CB8 and LCA 0 in the
following order:
a
remove -48V line drawer fuses 11 to 15
b
remove fuse F01 of the FSP, associated with CB8 only
c
unseat NT repeater cards 1 to 4.
d
Go to step 34.
Remove the fuses and repeaters associated with CB8 and LCA 0 in the
following order:
a
remove -48V line drawer fuses, 11 through 15
b
unseat NT repeater cards, 5 through 7.
0 C
0
0
Host XPM P-side link number
Do
step 32
step 33
ES SES STATE
1
0
0
ManB