Nortel DMS-100 Series Maintenance Manual page 475

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Replacing an NT6X50 card in an HIE
At your Current Location
1
Obtain a replacement card. Ensure that the replacement card has the same
product equipment code (PEC), including suffix, as the card that is to be
removed.
2
If you were directed to this procedure from another maintenance procedure,
go to step 4; otherwise, continue with step 3.
At the MAP display
3
Access the PM level and post the LCM by typing
>MAPCI;MTC;PM;POST LCM site frame lcm
and pressing the Enter key.
where
site
is the name of the OPM site (alphanumeric)
frame
is the frame number of the OPM (0 to 511)
lcm
is the number of the LCM
4
Display C-side link information by typing
> TRNSL C
and pressing the Enter key.
Example of a MAP response:
Link 0: LTC 0
Link 1: LTC 0
5
From the display in step 4, determine the C-side peripheral module (LTC,
LGC, or RCC) to which the OPM is connected and post it by typing
> POST host_pm host_pm_no
and pressing the Enter key.
where
host_pm
is the name of the host PM (LTC, LGC, or RCC)
host_pm_no
is the number of the host PM
OPM card replacement procedures
LTC P-side link numbers
2; Cap MS; Status: OK
6; Cap MS; Status: SysB
DMS-100 Family OPM Maintenance Manual XPM14 and up
in an OPM HIE
;MsgCond: OPN
;MsgCond: CLS
8-135
NT6X50
(continued)

Advertisement

Table of Contents
loading

Table of Contents