Nortel DMS-100 Series Maintenance Manual page 231

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

23
Before you perform a manual restore on the OPM from ESA, check if the links
to the OPM are stable To find the link numbers for this OPM, type:
>TRNSL C
and press the Enter key.
Example of a MAP response:
Link
0:
LTC 1
Link
1:
LTC 1
Link
2:
LTC 1
Link
3:
LTC 1
24
To access the CARRIER level of the MAP terminal, type:
>TRKS;CARRIER
and press the Enter key.
25
To post the host XMS-based peripheral module (XPM) links and check link
conditions for slips and framing errors, type:
>POST pm_type pm_no link_no
and press the Enter key.
where
pm_type
is an LGC, LTC, or RCC
pm_no
is the number of the PM zero to 127
link_no
is the number of the link associated with the host XPM. Refer to step
23 display.
Repeat the POST command for each link.
Example MAP response:
N CLASS
SITE LTC CK D ALRM SLIP FRME
0 REMOTE HOST
where
The number that appears under the CK (circuit) header is the host XPM link
number.
Note: This display shows carrier facilities from the host XPM to the OPM.
Use the Detail REM option to check the carrier facilities from the remote
site back to the host XPM.
If link conditions
display a high number of SLIP
and FRME
OPM alarm clearing procedures
0;Cap MS;Status:OK
2;Cap MS;Status:OK
3;Cap
4;Cap
1
0 C
0
DMS-100 Family OPM Maintenance Manual XPM14 and up
critical
;MsgCon:OPN
;MsgCon:OPN
S;Status:OK
S;Status:OK
BER
ES SES STATE
0
1
0
Do
Leave the OPM in ESA. Go to
step 32.
7-11
LCM
(continued)
0
INSV

Advertisement