Nortel DMS-100 Series Maintenance Manual page 227

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

6
To identify the OPM that has faults, type:
>DISP STATE CBSY LCM
and press the Enter key.
If response
indicates no CBsy LCMs
indicates CBsy LCMs
7
To post the OPM with the alarm condition, type:
>POST LCM CBsy
and press the Enter key.
Note the name and number of this OPM.
8
To identify central side (C-side) links to the host PM, type:
>TRNSL C
and press the Enter key.
Example of a MAP response:
Link 0: LTC 0
Link 1: LTC 0
9
To post the host PM, type:
>POST pm pm_no
and press the Enter key.
where
pm
is a line group controller (LGC), line trunk controller (LTC), or remote
cluster controller (RCC)
pm_no
is the number of the PM
10
To display the peripheral-side (P-side) links, type:
>TRNSL P
and press the Enter key.
Example of a MAP response:
Link 2: LCM REM1 00 0
Link 6: LCM REM1 00 0
Record information for the links that have a status other than OK.
11
To busy the link that has faults, type:
>BSY LINK link_no
and press the Enter key.
2; Cap MS; Status: SysB
6; Cap MS; Status: SysB
2; Cap MS; Status: SysB ;MsgCond: CLS
1; Cap MS; Status: SysB ;MsgCond: CLS
DMS-100 Family OPM Maintenance Manual XPM14 and up
OPM alarm clearing procedures
critical
Do
step 17
step 7
;MsgCond: CLS
;MsgCond: CLS
7-7
LCM
(continued)

Advertisement

Table of Contents
loading

Table of Contents