Replacing an NT2X90 card in an RMM
At your current location
1
Proceed only if you were either directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure to verify or
accept cards, or were directed to this procedure by your maintenance support
group.
2
Obtain a replacement card. Ensure that the replacement card has the same
product equipment code (PEC) including suffix, as the card to be removed.
At the MAP display
3
Access the PM level and post the RMM by typing
>MAPCI;MTC;PM;POST RMM rmm_no
and pressing the Enter key.
where
rmm_no
is the number of the RMM from which the card is to be removed
Example of a MAP display:
CM
MS
IOD
.
.
RMM
0 Quit
PM
2 Post_
RMM
3
4
RMM
5 Trnsl
6 Tst
7 Bsy
8 RTS
9 OffL
10 LoadPM
11 Disp_
12 Next
13
14 QueryPM
15
16
17
18
4
Busy the RMM by typing
>BSY
and pressing the Enter key.
OPM card replacement procedures
Net
PM
CCS
.
.
4SysB
.
SysB
ManB
OffL
4
0
0
1
5
INSV
DMS-100 Family OPM Maintenance Manual XPM14 and up
in an OPM RMM
LNS
Trks
Ext
.
.
CBsy
ISTb
10
3
3
1
0
0
8-77
NT2X90
(continued)