7-90 OPM alarm clearing procedures
LCM
minor
(continued)
24
25
26
297-8361-550 Standard 04.01 September 2000
To test both line subgroups associated with the drawer that has faults, type
>TST DRWR
lsg
and press the Enter key.
where
lsg
is the number of one of the line subgroups associated with the
drawer that has faults.
Note: Repeat this step for the other line subgroup associated with the
drawer that has faults.
If test
passed
failed, and the system produces
a card list
failed, but the system does not
produce a card list
To return to service both line subgroups, type
>RTS DRWR
lsg
and press the Enter key.
where
lsg
is the number of one of the line subgroups associated with the
drawer that has faults
Example of a MAP response:
OSvce Tests Initiated
LCM
REM1 00 0
LCM
REM1 00 0
Repeat this step for the other line subgroup associated with the drawer that
has faults.
If return to service
passed
failed
To busy the LCM unit associated with the alarm, type
>BSY UNIT Icm_unit
Do
step 25
step 29
step 30
Drwr 2 Tst Passed
Drwr 2 Rts Passed
Do
step 32
step 30