Nortel DMS-100 Series Maintenance Manual page 323

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Example of a MAP response :
Link 0: LCM 0
Link 1: LCM 0
Record information for the ESA links that have a status other than OK.
6
To post the OPM associated with the link that has faults, type:
>POST LCM site frame lcm
and press the Enter key.
where
site
is the site name of the OPM (alphanumeric)
frame
is the frame number of the OPM (0 to 511)
lcm
is the number of the LCM (0 to 1)
7
To identify the peripheral-side (P-side) links that have faults and associate
with ESA, type:
>TRNSL
P
and press the Enter key.
Example of a MAP response :
Link 0: RMM 0
Link 1: RMM 0
Link 2: ESA 0
Link 3: ESA 0
Record information for the ESA links that have a status other than OK.
8
To busy the link that has defects, type:
>BSY LINK link_no
and press the Enter key.
where
link_no
is the number of a P-side link identified in step 7
9
To test the busied link, type:
>TST LINK link_no
and press the Enter key.
where
OPM alarm clearing procedures
0;Cap M ;Status:SysB
1;Cap M ;Status:SysB
0;Cap MS;Status:OK
1;Cap MS;Status:OK
0;Cap M ;Status:SysB
1;Cap M ;Status:SysB
DMS-100 Family OPM Maintenance Manual XPM14 and up
critical, minor
(continued)
;MsgCond:CLS
;MsgCond:CLS
;MsgCond:OPN
;MsgCond:OPN
;MsgCond:CLS
;MsgCond:CLS
7-103
ESA

Advertisement

Table of Contents
loading