Nortel DMS-100 Series Maintenance Manual page 251

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Link
0: LTC 0
Link
1: LTC 0
Link
2: LTC 0
Link
3: LTC 0
25
To post the host peripheral, type
>POST pm_type pm_no
and press the Enter key.
where
pm_type
is the name of the host XPM (LGC, LTC, or RCC)
pm_no
is the number of the host XPM
26
To display the P-side links, type
>TRNSL P
and press the Enter key.
Example of a MAP response:
Link 0: LCM REM1 00 0
Link 1: LCM REM1 00 0
Record information for the links that you must busy.
27
To busy the links, type
>BSY LINK link_no
and press the Enter key.
where
link_no
is the number of a P-side link that interfaces the OPM
Note: Perform this step for each link that interfaces the OPM unit busied
in step 23.
28
To access the CARRIER level of the MAP display, type
>trks;carrier
and press the Enter key.
29
To post the P-side links of the host XMS-based peripheral module (XPM),
type
>POST pm_type pm_no link_no
and press the Enter key.
where
OPM alarm clearing procedures
Host XPM type and number
0;Cap
MS;Status:OK
1;Cap
MS;Status:OK
3;Cap
s;Status:OK
4;Cap
S;Status:OK
2;Cap MS;Status:OK;
1;Cap MS;Status:OK;
DMS-100 Family OPM Maintenance Manual XPM14 and up
LCM talk battery alarm
critical
(continued)
;MsgCon:CLS
;MsgCon:CLS
MsgCond: CLS
MsgCond: CLS
7-31