5-8 OPM hardware
Figure 5-2 Bay frame and equipment arrangement, OPM-640 (NT8X01AA, AB)
End–access compartment
Additional OPM components
The following sections describe optional components that are available for
both the OPM-640 and the OPM-256.
Calibration device
The OPM-640 and the OPM-256 can support the installation of a calibration
device. This device tests for calibration of the Digital Remote Test Unit
(DRTU) testing equipment. A small case, approximately 76 mm by 114 mm
by 36 mm (3 in by 4.5 in by 1.4 in), contains the calibration device. The small
case is mounted above the utility power breaker. Refer to the figure "OPM bay
frame and equipment arrangement OPM-640 (NT8X01AA, AB)".
297-8361-550 Standard 04.01 September 2000
Fuse panels
LCA-1
LCA-0
HIE
ECU
BAY 0
Battery control unit (BCU)
0 0
DS1
Repeater
Cards
RMM
ECU
BAY 1
Door switch
RECT1
PCU
RECT0
FSP