Nortel DMS-100 Series Maintenance Manual page 242

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

7-22 OPM alarm clearing procedures
LCM (RG)
critical
(continued)
13
14
15
16
297-8361-550 Standard 04.01 September 2000
Example of a MAP display:
LCM REM1 14 1 Unit 1 SWRG Passed
If the SWRG command
passes, and you must switch RG
activity for the other unit
passes, and RG activity is cor-
rect for both units
fails
Repeat step 12 for the other LCM unit.
To test the new RG, type
>TST
UNIT unit_no
and press the Enter key.
where
unit_no
is the number of the LCM unit (0 or 1) associated with the new RG.
Example of a MAP response:
LCM REM1 00 0 Unit 1 InSvce Tests Initiated
LCM REM1 00 0 Unit 1 Tst Passed
If TST
passes
fails
Repeat steps 7 to 14 for the other LCM unit.
To align RG activity to the selected RG, type
>SWRG UNIT unit_no
and press the Enter key.
where
unit_no
is the LCM unit (0 or 1) associated with the new RG
Example of a MAP display:
LCM REM1 00 0 InSv Links OOS: Cside 0 Pside 0
Unit 0: InSv
/RG:0
Unit 1: InSv
/RG:0
11 11 11 11 11 RG: Pref 0 InSv
Drwr: 01 23 45 67 89 01 23 45 67 89
.. .. .. .. .. ..
Do
step 13
step 13
step 18
Do
step 15
step 18
Stby 1 InSv
.. .. .. ..