7-68 OPM alarm clearing procedures
Ext FSP
OPM cabinet major
97
98
99
100
101
102
297-8361-550 Standard 04.01 September 2000
(continued)
Determine if the pins on the backplane of the shelf are bent or short-circuited.
If the pins
are bent or short-circuited
are not bent or short-circuited, and the converter is an
NT6X53
are not bent or short-circuited, and the converter is
not an NT6X53
Set the circuit breaker to OFF.
Straighten or replace bent or short-circuited pins. Go to step 96.
Insert the NT6X51 and the NT6X52cards on the shelf.
Set the circuit breaker to ON.
If the CONVERTER FAIL LED
is lit
is not lit
Use the following table and diagram to identify the alarm and control card
associated with the shelf with the lit CONVERTER FAIL LED.
Shelf number
NT2X70 in slot 25 row A bay 0 shelf 05
NT2X70 in slot 22 row A bay 0 shelf 05
NT2X09 in slot 17 and 20 row A bay 1 shelf 05
NT6X53 in slot 1 row A bay 0 shelf 19 and 33
NT6X60 in slots 1 and 5 row A bay 0 shelf 05
Do
step 98
step 100
step 102
Do
step 102
step 105
Alarm and
Card
control card
position
slot CD2
center
NT0X91AE
slot CD3
left
NT0X91AA
slot CD2
center
NT0X91AE
slot CD1
right
NT6X36
slot CD1
right
NT6X36