8-198 OPM card replacement procedures
NT6X75
in an OPM HIE
Summary of card replacement procedures for an NT6X75 card in an HIE
At the PM level,
post the IstB LCM.
Busy unit 0.
Post and busy the
ESA processor.
Replace the card
with one having the
identical PEC.
Post the LCM
associated with the
faulty NT6X75.
Return unit 0 to
service.
Replacing an NT6X75 card in an HIE
At your Current Location
1
2
3
297-8361-550 Standard 04.01 September 2000
(continued)
Post and reload the
ESA processor.
Return the ESA
processor to
service.
End of the
procedure
Proceed only if you have been directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure for verifying
or accepting cards, or have been directed to this procedure by your
maintenance support group.
Obtain a replacement card. Ensure that the replacement card has the same
product equipment code (PEC), including suffix, as the card that is to be
removed.
If you were directed to this procedure from another maintenance procedure,
go to step 10; otherwise, continue with step 4.