29
Leave the disk utility by typing
>QUIT
and pressing the Enter key.
30
Reload the RMM by typing
>LOADPM
and pressing the Enter key.
If
load failed
load passed
31
Return the RMM to service by typing
>RTS
and pressing the Enter key.
If RTS
passed
failed
32
Go to the TTP level of the MAP and post the RMM by typing
>TRKS;TTP;POST P RMM rmm_no
and pressing the Enter key.
33
Return to service the circuits by typing
>RTS ALL
and pressing the Enter key.
where
rmm_no
is the number of the RMM shelf in which the card is to be replaced
If RTS
passed
failed
34
Send any faulty cards for repair according to local procedure.
35
Record the following items in office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
OPM card replacement procedures
in an OPM RMM
DMS-100 Family OPM Maintenance Manual XPM14 and up
Do
step 36
step 31
Do
step 32
step 36
Do
step 34
step 36
8-35
NT2X09
(continued)