Lcm Talk Battery Alarm Critical - Nortel DMS-100 Series Maintenance Manual

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

7-24 OPM alarm clearing procedures
LCM talk battery alarm
critical
Alarm display
CM
.
Indication
The following text beneath the PM header at the MTC level of the MAP
display indicates an alarm in an outside plant module (OPM):
Meaning
One or both units of the OPM do not have a talk battery.
Result
If circuit breaker CB8 is affected, call processing ceases. There is no alarm.
If circuit breaker CB9 is affected, call processing ceases. An alarm sounds to
indicate this condition.
Common Procedures
There are no common procedures.
Action
This section provides a summary flowchart of the procedure and a list of steps
to clear an alarm. Use the flowchart to review the procedure. Follow the steps
to perform the procedure.
297-8361-550 Standard 04.01 September 2000
MS
IOD
Net
.
.
an n next to the LCM indicates the number of LCM modules affected
a *C* indicates that the alarm class is critical
PM
CCS
.
nLCM
.
*C*
Lns
Trks
Ext
.
.
.
Appl
.