Nortel DMS-100 Series Maintenance Manual page 463

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

Replacing an NT6X45 card in an HIE
At your Current Location
1
Obtain a replacement card. Verify that the replacement card has the same
product engineering code (PEC), including suffix, as the card to be removed.
2
If you were directed to this procedure from another maintenance procedure,
go to step 5; otherwise, continue with step 3.
At the MAP terminal
3
Post the ESA processor by typing
>MAPCI;MTC;PM;POST ESA esa_no
and pressing the Enter key.
where
esa_no
is the number of the ESA processor (0 to 255)
4
Busy the ESA processor by typing
>BSY
and pressing the Enter key.
Example of a MAP response:
This action will take this PM out of service
Please confirm ("Yes" or "No")
Respond by typing
>YES
and pressing the Enter key.
At the OPM cabinet
5
Replace the NT6X45 card using the common replacing a card procedure in
this document . When you have completed the procedure, return to this point.
6
If you were directed to this procedure from another maintenance procedure,
return now to the procedure that directed you here and continue as directed;
otherwise, continue with step 7.
7
Load the ESA processor by typing
>LOADPM
and pressing the Enter key.
If
message "loadfile not found in
directory" is received
load passes
OPM card replacement procedures
DMS-100 Family OPM Maintenance Manual XPM14 and up
in an OPM HIE
Do
step 8
step 26
8-123
NT6X45
(continued)