7-36 OPM alarm clearing procedures
LCM talk battery alarm
critical
(end)
55
56
57
297-8361-550 Standard 04.01 September 2000
where
lcm_unit
is the LCM unit busied in step 23
If the test
passed
failed
To return to service (RTS) the LCM unit, type
>RTS UNIT lcm_unit
and press the ENTER key.
where
lcm_unit
is the LCM unit tested in step 54
For additional help, contact the next level of support.
The procedure is complete. If other alarms appear, refer to the correct alarm
clearing procedures for the indicated alarms.
Do
step 55
step 56