Nortel DMS-100 Series Maintenance Manual page 476

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-136 OPM card replacement procedures
NT6X50
in an OPM HIE
6
7
8
9
297-8361-550 Standard 04.01 September 2000
(continued)
Display P-side link information by typing
> TRNSL P
and pressing the Enter key.
Example of a MAP response:
Link 2: LCM REM1 00 0
Link 6: LCM REM1 00 0
Record the numbers of the links with status not OK.
Use the following diagram to determine which DS-1 interface card or cards
corresponds to the links identified as faulty in step 6. Note that each NT6X50
card has 2 ports. For example, the faulty link 6 displayed in step 6 is
connected to port 1 as indicated, which corresponds to the NT6X50 in slot 20.
Port numbers
Slot numbers
Determine the slot location of the faulty card.
If faulty card is in slot
19 or 20 of the HIE
21 of the HIE
Post the LCM by typing
>POST LCM site frame lcm
and pressing the Enter key.
where
site
is the name of the OPM site (alphanumeric)
frame
is the frame number of the OPM (0-511)
lcm
is the number of the LCM
NT6X50 port numbers
0;Cap MS;Status:OK
1;Cap MS;Status:SysB ;MsgCond: CLS
6
6
6
X
X
X
5
5
5
0
0
0
0
1
4
2
3
5
19
20
21
Do
step 9
step 12
;MsgCond: OPN