2-72 Functional overview
The alarms that relate to the OPM appear in the following table. These alarms
appear under the PM subsystem header of the MAP display.
Table 12 Alarm class codes, displays, and conditions
PM header display
PM
PM
nnSysB
*C*
PM
nnLCM
*C*
PM
LCMRG
M
PM
nnSysB
M
PM
LCMRG
(blank)
PM
nnISTb
(blank)
PM
nnCBsy
(blank)
PM
nn ManB
(blank)
297-8361-550 Standard 04.02 December 2004
Note: When nn is greater than 99, two asterisks (**) appear instead of
numbers.
Condition
All PMs are in service. Alarm conditions are not in
effect.
More than 10% of the PMs are SysB-critical alarm.
Both units of one or more LCMs are not in-service
critical alarm.
Both RGs of an OPM have ISTb and a critical or major
alarm is not present.
10% or fewer of the PMs are SysB major alarm.
One RG of an OPM has ISTb, and a critical or major
alarm is not present.
The indicated number of PMs are ISTb.
The indicated number of PMs are CBsy.
The indicated number of PMs are ManB minor alarm.