Figure 16 Talk battery distribution on RLCE frame
RLCE
FSP
RMM
cooling baffle
LCA–1
LCA–0
cooling baffle
Talk battery return
For redundancy of return
The A feed provides talk battery for LCA-1 and the B feed provides talk
battery for LCA-0. The feeds are not redundant, which can affect up to 320
subscriber lines. Some redundancy with the talk battery returns to avoid an
outage by a single fault.
In the past, operating company personnel did not receive an indication of a
problem before a loss of talk battery unless the talk battery fuse had blown.
The LCM indicates InSv (in service) on the MAP display to indicate a blown
fuse. The LCM performs a line card audit. This audit cannot check for loss of
DMS-100 Family OPM Maintenance Manual ISN07 (TDM)/SN07 (DMS) and up
HIE
Talk battery fuses
Talk battery A feed
Talk battery
fuses
Talk battery B feed
Functional overview 2-45
Power
distribution
center

Advertisement