Replacing an NT6X53 card in an OPM
At your Current Location
1
Proceed only if you were either directed to this card replacement procedure
from a step in a maintenance procedure, are using the procedure to verify or
accept cards, or were directed to this procedure by your maintenance support
group.
2
Obtain a replacement card. Ensure that the replacement card has the same
product equipment code (PEC), including suffix, as the card that is to be
removed.
At the MAP display
3
Access the PM level of the MAP and post the LCM by typing
>MAPCI;MTC;PM;POST LCM site frame lcm
and pressing the Enter key.
where
site
is the name of the OPM site
frame
is the frame number of the OPM cabinet (0 to 511)
lcm
is the number of the LCM
Example of a MAP display:
CM
MS
IOD
.
.
.
LCM
0 Quit
PM
2 Post_
LCM
3
4 SwRg
5 Trnsl
6 Tst
7 Bsy
8 RTS
9 OffL
10 LoadPM
11 Disp_
12 Next
13
14 QueryPM
15
16
17
18
OPM card replacement procedures
Net
PM
CCS
.
1LCM
.
SysB
ManB
OffL
0
1
0
0
1
0
LCM
Rem1
OO O ISTb
Unit–0:
InSv
Mtce TakeOver
Unit–1:
SysB
Mtce
Drwr: 01 23 45 67 89 01 23 45 67 89
.. .. .. .. .. .. .. .. .. ..
DMS-100 Family OPM Maintenance Manual XPM14 and up
in an OPM
LNS
Trks
Ext
.
.
.
CBsy
ISTb
0
0
0
0
Links_OOS: CSide 0 PSide 0
/RG:
0
/RG:
0
11 11 11 11 11 RG:Pref:0 InSv
Stby:1 InSv
8-155
NT6X53
(continued)
Appl
.
InSv
130
0

Advertisement

Table of Contents
loading

Table of Contents