Nortel DMS-100 Series Maintenance Manual page 409

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

35
Return the LCM unit to service by typing
>RTS
and pressing the Enter key.
If RTS
passed
failed
At the MAP display
36
Post the OPM associated with the faulty NT2X70 card by typing
>POST LCM site_name frame_no lcm_no
and pressing the Enter key.
where
site_name
is the name of the site where the OPM is located
frame_no
is the number of the frame where the LCM is located
lcm_no
is the number of the LCM module in the frame
37
Busy unit 1 of the OPM by typing
>BSY UNIT 1
and pressing the Enter key.
38
Post the ESA processor identified in step 4 by typing
>POST ESA esa_no
and pressing the Enter key.
where
esa_no
is the number of the ESA processor associated with the faulty NT2X70
card.
39
Busy the ESA processor by typing
>BSY
and pressing the Enter key.
Example of a MAP response:
This action will take this PM out of service
Please confirm ("Yes" or "No")
Respond to the system prompt by typing
>YES
OPM card replacement procedures
DMS-100 Family OPM Maintenance Manual XPM14 and up
in an OPM HIE
Do
step 69
step 73
8-69
NT2X70
(continued)