3-4 PRLCM overview
The ringing generators also produce voltages required for ANI and coin
control (48 V dc and 130 V dc). They monitor ANI and coin voltages and ring
bus outputs for failure.
Link control cards
The two LCCs fill slots 17 and 18 of the HIE. Each LCC provides an interface
between eight DS30A ports from an PRLCM LCA shelf and the PCM30 links
to the host office. The LCCs also provide an interface between the ESA
processor, if provisioned, and the ILCM. The following figure shows how the
PCM30 links are terminated on the LCC and in the LCA.
Figure 3-2 LCC interface to PCM30 interface cards
Under normal conditions, when both are active, LCC-0 connects LCA-0, and
LCC-1 connects LCA-1. LCC-0 serves even numbered PCM30 links (0, 2,
and 4) from the PCM30 interface cards, and LCC-1 serves odd numbered
PCM30 links (1, 3, and 5). The following figure shows how the LCCs are
configured in the PRLCM.
297-8361-550 Standard 04.01 September 2000
PCM30
0
links
PCM30
interface
card
DS30A links
LCA-0
To host office
2
4
PCM30
interface
card
I/S
LCC-0
LCC-1
RMM
5
1
3
PCM30
interface
card
I/S: intershelf link
DS30A links
LCA-1