Nortel DMS-100 Series Maintenance Manual page 263

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

and press the Enter key.
Example of a MAP response:
Link 2:LCM REM1 00 0
Link 6:LCM REM1 00 0
Record information for the links that have a status other than OK.
12
To busy the link that has faults, type
>BSY LINK link_no
and press the Enter key.
where
link_no
is the number of a P-side link identified in step 11
13
To test the busied link, type
>TST
LINK link_no
and press the Enter key.
where
link_no
is the number of a P-side link busied in step 12
If test
passes
fails
14
To return the busied link to service, type
>RTS
LINK
and press the Enter key.
where
link_no
is the number of a P-side link busied in step 12
If RTS
passes and other links are not
SysB
passes but other links are SysB
fails
15
To post the OPM with the alarm condition, type
>POST LCM site frame
OPM alarm clearing procedures
0;Cap MS;Status:OK
1;Cap MS;Status:SysB ;MsgCond: CLS
link_no
lcm
DMS-100 Family OPM Maintenance Manual XPM14 and up
major
;MsgCond: OPN
Do
step 14
step 21
Do
step 15
step 12
step 21
7-43
LCM
(continued)