2-48 Functional overview
The MAP commands that can Bsy the last available WLC on an LCM shelf are
modified. The commands are modified to issue a warning message when this
condition occurs. Three commands can cause this condition.
The issue of one of these commands can cause the Bys of the last available
WLC on the LCM shelf. When this event occurs, a warning message appears
at the MAP terminal. An example of this message follows:
Example of a MAP response:
Busying the last available WLC on LCM shelf.
testing for talk battery failure on the LCM shelf. Minor alarm
will be raised within one minute unless WLC becomes available.
The QUERYPM FLT command is modified to display the new ISTb reasons
by shelf and LEN for the two alarm conditions. An example of this display
follows:
Example of a MAP response:
Node inservice trouble exist:
One or both units Inservice Trouble:
LCM UNIT 0 Inservice Trouble Exist:
Talk Battery failure detected on shelf <shelf #> by <LEN>
LCM UNIT 1 No Faults Exist
or
Node inservice trouble exist:
One or both units Inservice Trouble:
LCM UNIT 0 Inservice Trouble Exist:
LCM UNIT 1 No Faults Exist
The MAP commands that can RTS the first available WLC on an LCM shelf
are modified to issue the following notification messages. This notification
message informs the operating company personnel that the minor alarm and
ISTb reason for the LCM shelf is cleared. This condition occurs because a
WLC is made available to test for talk battery failures. Two commands can
297-8361-550 Standard 04.02 December 2004
the Bsy command at the LTP MAP level when a WLC is posted
the Diag command at the LTP MAP level when a WLC is posted. Diag is
temporarily ManB the WLC
the Bsy Drwr command at the PM MAP level when an LCM is posted
This prevents