Nortel DMS-100 Series Maintenance Manual page 344

Hide thumbs Also See for DMS-100 Series:
Table of Contents

Advertisement

8-4 OPM card replacement procedures
NT0X10
in an OPM RMM
Replacing an NT0X10 card in an RMM
At your current location
1
At the MAP display
2
At the RMM shelf
3
4
297-8361-550 Standard 04.01 September 2000
(continued)
Obtain a replacement card. Ensure that the replacement card has the same
product equipment code (PEC), including suffix, as the card to be removed.
Access the TTP level of the MAP and post the scan points on the card to be
replaced by tying
>MAPCI;MTC;TRKS;TTP;POST P RMM rmm_no ckt_no
and pressing the Enter key.
rmm_no
is the number of the RMM with the faulty NT0X10 card.
ckt_no
is the number of the first scan point (SC) of the seven SC points on this
card.
Example of a MAP display response:
LAST CIRCUIT = 14
POST CKT IDLED
SHORT CLLI IS:
OK, CLLI POSTED
POST
13
DELQ
TTP 6–006
CKT TYPE
PM NO.
OG TESTEQ
RMM 0 0
DANGER
Static electricity damage
Wear a wrist strap connected to the wrist strap grounding
point of a frame supervisory panel (FSP) while handling
circuit cards. This protects the cards against damage caused
by static electricity.
Replace the NT0X10 card using the common replacing a card procedure in
this document. When you have completed the procedure, return to this point,
otherwise go to step 6.
Send any faulty cards for repair according to local procedure.