8-68 OPM card replacement procedures
NT2X70
in an OPM HIE
26
27
28
29
30
31
32
33
34
297-8361-550 Standard 04.01 September 2000
(continued)
List the IOC file names into your user directory by typing
>LISTVOL volume_name ALL
and pressing the Enter key.
where
volume_name
is the name of the volume that contains the PM load files, obtained in
step 24.
Leave the disk utility by typing
>QUIT
and pressing the Enter key.
Go to step 34.
From office records, determine and note the number of the system load
module (SLM) disk and the name of the volume that contains the PM load
files.
Access the disk utility level of the MAP by typing
>DISKUT
and pressing the Enter key.
List the SLM disk volume names by typing
>LV CM
and pressing the Enter key.
List the SLM file names into your user directory by typing
>LF volume_name
and pressing the Enter key.
where
volume_name
is the name of the volume that contains the PM load files, obtained in
step 29.
Leave the disk utility by typing
>QUIT
and pressing the Enter key.
Load the LCM unit by typing
>LOADPM
and pressing the Enter key.
If loadpm
passed
failed
Do
step 35
step 73