7-12 OPM alarm clearing procedures
LCM
critical
(continued)
26
27
28
29
297-8361-550 Standard 04.01 September 2000
If link conditions
display a very low number of
SLIP and FRME
To post the OPM with the alarm condition, type:
>PM;
POST LCM site frame lcm
and press the Enter key.
where
site
is the site name of the OPM (alphanumeric)
frame
is the frame number of the OPM (0 to 511)
lcm
is the number of the LCM unit of the OPM
To busy both LCM units of the OPM, type:
>BSY PM
and press the Enter key.
Go to step 30.
To test both LCM units of the OPM, type:
>TST PM
and press the Enter key.
If test
passed
failed, and the system generated
a card list
failed, and the system did not
generate a card list
The card list identifies the cards at risk for faults. Replace the cards one at a
time in the order listed.
If you
did not replace the last card on
the list
did replace the last card on the
list
Do
step 26
Do
step 30
step 29
step 33
Do
step 34
step 33