N CLASS SITE LTC CK D ALARM SLIP FRAME
0 REMOTE HOST 0
50
To busy the links offlined in step 30, type
>BSY item_no
and press the Enter key.
where
item_no
is the item number under the n (0 to 4) column
Note: Perform this step for each link offlined before.
51
To access the PM level of the MAP display and post the host peripheral, type
>PM;POST pm_type pm_no
and press the Enter key.
where
pm_type
is the name of the host XPM (LGC, LTC, or RCC)
pm_no
is the number of the host XPM
52
To return to service the links busied in step 27, type
>RTS LINK link_no
and press the Enter key.
where
link_no
is the number of a P-side link that interfaces to the OPM
Note: Perform this step for each manually busied link.
53
To post the OPM, type
>POST LCM site frame lcm
and press the Enter key.
site
is the site name of the OPM (alphanumeric)
frame
is the frame number of the OPM (0 to 511)
lcm
is the number of the LCM
54
To test the LCM unit, type
>TST UNIT lcm_unit
and press the ENTER key.
OPM alarm clearing procedures
0 C
0
Host XPM P-side link number
DMS-100 Family OPM Maintenance Manual XPM14 and up
LCM talk battery alarm
critical
(continued)