8-96 OPM card replacement procedures
NT6X18
in an OPM
(end)
At the MAP terminal
6
There is a new diagnostics test for NT6X18AA/AB cards. This NT6X18 card may be
good. See the NT6X18 line card description in the general maintenance section of this
book for information on running an enhanced diagnostics.
7
8
9
10
11
297-8361-550 Standard 04.01 September 2000
Test the line card just replaced by typing
>DIAG
and pressing the Enter key.
If DIAG
passed
failed
Return the line card to service by typing
>RTS
and pressing the Enter key.
If RTS
passed
failed
Send any faulty cards for repair according to local procedure.
Record the following items in office records:
date the card was replaced
serial number of the card
symptoms that prompted replacement of the card
Go to step 11.
Obtain further assistance in replacing this card by contacting the personnel
responsible for higher level of support.
You have successfully completed this procedure.
ATTENTION
Do
step 7
step 10
Do
step 8
step 10